Skip to Content
LGPS 1104 Electroless Nickel Plating · Collins Aerospace Approved Processor — Entech
CUSTOMER APPROVAL · COLLINS AEROSPACE
LGPS 1104 · APPROVED PROCESSOR

LGPS 1104 Electroless Nickel, Certified by Collins.

Entech is a Collins Aerospace-approved processor for LGPS 1104 electroless nickel plating, executed under NADCAP Chemical Processing accreditation. Landing-gear and structural-aerospace components, processed against the LGPS 1104 callout and shipped worldwide.

Approved on
NADCAP CP AS9100D ISO 9001:2015

What LGPS 1104 means on a print — and why it matters.

LGPS 1104 sits at the intersection of aerospace structural reliability and chemical-process discipline. When it appears on a Collins drawing, the part isn’t a candidate for a generic plating shop. Below is what the callout actually requires.

LGPS 1104 is Collins Aerospace’s Landing Gear Plating Specification 1104 — the customer-controlled standard for electroless nickel plating on landing-gear and adjacent structural-aerospace components built under Collins programs. It defines the chemistry envelope, deposit characteristics, allowable substrates, post-treatment requirements, and inspection criteria that an electroless nickel deposit must satisfy before a part is accepted into a Collins assembly.

The specification exists because landing-gear and load-path structural components live at the demanding end of the aerospace duty envelope: cyclic loading, fatigue, corrosive service environments, and tight dimensional tolerance after build-up. A generic "per ASTM B733" deposit doesn’t satisfy LGPS 1104 by itself — the callout layers Collins-specific bath-control, hardness, post-bake, and adhesion criteria on top of the public-spec foundation.

What LGPS 1104 actually controls, in plain English: which platers can run it (only NADCAP-accredited approved processors), how the bath is run (phosphorus content, temperature, pH, replenishment cycle), what the deposit must measure (thickness range, hardness as-plated and post-heat-treat, adhesion), what substrates are allowed, and how the part is post-treated (hydrogen-embrittlement relief bake on high-strength steels; optional heat treatment to elevate hardness). Get one of those wrong, and the part isn’t LGPS 1104 — even if the deposit looks right.

For procurement engineers, the practical consequence is simple: LGPS 1104 work must be sourced from a Collins-approved processor with current NADCAP Chemical Processing accreditation, full traceable lot records, and a quality system that stands up to a Collins source-survey audit. Entech is on that list.

Issuing Body
Collins Aerospace
Raytheon Technologies aerospace systems business unit. Specification owner for the LGPS family of landing-gear plating standards.
Plating Type
Electroless Ni-P
Autocatalytic nickel-phosphorus deposit. No external current. Uniform coverage on internal features and complex geometries.
Typical Thickness
0.0005–0.003″
Per drawing callout. Common range 12–75 µm. Heavier build-up acceptable on engineering review.
Common Substrates
Steel · SST · Al · 300M
Carbon and alloy steels, stainless, aluminum, copper alloys, Invar 36, Inconel, plus high-strength steels including 300M.

The numbers behind LGPS 1104.

Use this matrix as a starting point when scoping a part to LGPS 1104. The exact values for any given component come off the drawing — we cross-reference each callout against the live specification before quoting.

Parameter Typical LGPS 1104 Range Process Notes
Phosphorus Content 10.5–13 wt % High-phosphorus deposit. Maximum corrosion resistance and amorphous as-plated structure. Bath chemistry maintained inside the LGPS 1104 envelope by daily titration.
Deposition Rate 12–20 µm / hr Bath temperature (88–92 °C) and pH (4.6–5.0) controlled to deliver predictable plate-time per drawing thickness.
Hardness, As-Plated ~500 HV / ~48 HRC Amorphous Ni-P matrix. Naturally hard but ductile relative to electrodeposited chromium. Acceptable for service without further heat treatment when drawing permits.
Hardness, Post Heat Treat ~900–1000 HV / 65–70 HRC Optional precipitation heat treat at 350–400 °C / 1–4 hr precipitates Ni₃P and elevates hardness. Used when drawing calls for hard-EN equivalent to chrome.
Typical Thickness Range 0.0005–0.003″ (12–75 µm) Per drawing callout. Heavier build-up (up to 0.005″) on engineering review. Thinner values for corrosion-only callouts.
Embrittlement Relief Bake 190 °C / 23 hr min. Mandatory on high-strength steels (e.g., 300M, AerMet 100, 4340 above 1000 MPa) within 4 hours of plating to release diffused hydrogen.
Allowed Substrates Per LGPS 1104 § Carbon & alloy steels, stainless, aluminum (with appropriate strike), copper alloys, Invar 36, Inconel, 300M, AerMet, A286, beryllium copper. Each substrate has a controlled prep / activation sequence.
Adhesion Test Bend / Thermal-shock Sample coupons run with each lot. Visual inspection for blistering, peeling, or cracking after thermal-shock cycle confirms metallurgical bond.
Post-Treatment Options Bake · Heat treat · Polish Combinations applied per drawing: hydrogen relief, hardness elevation, dimensional polish to print. Selective masking available for non-plated zones.
Quality Documentation CofC + lot data Each shipment carries certificate of conformance citing LGPS 1104, NADCAP audit reference, lot ID, thickness verification, and bake record.
Note: ranges shown are typical values consistent with public LGPS 1104 guidance. The controlled specification governs the exact requirements for any given part — Entech runs each LGPS 1104 lot to the live, current revision of the specification on file, with full traceability into the Collins approval record.

How Entech runs an LGPS 1104 lot — from drawing to dock.

Each step exists to remove a variable. By the time your parts hit the bath, every Collins-controlled requirement — chemistry envelope, thickness range, post-treatment, lot documentation — is already locked.

01

Submit Drawing & LGPS 1104 Callout

You send the part drawing, material certificate, finish callout, and any program-level Collins requirements. We confirm LGPS 1104 revision, allowable substrate, and any masking or selective-plate zones before quoting.

02

Process Review & Engineering Sign-off

Process engineering matches the substrate to the right preparation, activation, and post-treatment sequence. Hydrogen-embrittlement relief bake and any heat-treat steps are scheduled into the route before the bath.

03

Plate to LGPS 1104

Bath chemistry, temperature, and pH controlled to the LGPS 1104 envelope. Real-time monitoring with daily titration. Thickness developed against the drawing tolerance, with selective masking applied where the print requires it.

04

Inspect, Document & Ship

Thickness verification, visual inspection, embrittlement-relief bake record, and certificate of conformance citing LGPS 1104 and NADCAP CP. Packaged for international export and shipped on schedule worldwide.

Related approvals, sibling specs, and the parent process.

LGPS 1104 lives inside a larger landscape of Collins Aerospace and aerospace-industry approvals. Here’s how to navigate from this page to the closest neighbours.

LGPS 1104 — the questions buyers ask us most.

Direct answers, with the specification numbers, certification IDs, and validity dates that aerospace procurement engineers need to evidence sourcing.

Q: Is Entech approved for Collins Aerospace LGPS 1104?
A: Yes. Entech holds active Collins Aerospace LGPS 1104 approval as an approved processor, executed under our NADCAP Chemical Processing accreditation (Cert 24321236442) valid through February 28, 2027.
Q: What is LGPS 1104?
A: LGPS 1104 is Collins Aerospace Landing Gear Plating Specification 1104, the electroless nickel plating standard for landing-gear and related aerospace structural components manufactured under Collins Aerospace programs.
Q: What substrates does Entech plate to LGPS 1104?
A: Entech plates to LGPS 1104 on carbon and alloy steels, stainless steel, aluminum, copper alloys, Invar 36, Inconel, and high-strength alloys including 300M. Each substrate has a tailored preparation, activation, and post-treatment sequence.
Q: Does Entech ship LGPS 1104 work internationally?
A: Yes. Entech ships LGPS 1104-processed components worldwide, with established workflows for Canadian, US, UK, French, and German aerospace customers.
Q: How do I request an LGPS 1104 quote from Entech?
A: Submit a quote request at https://enplating.ca/contactus with your part drawing, material, and finish callout. Entech responds with a process review and quote within one business day.

Talk to a process engineer about your LGPS 1104 part.

Send us the drawing, material certificate, and finish callout. We’ll confirm the LGPS 1104 revision against your program, scope the route, and respond with a quote and lead time inside one business day.

Cert 24321236442 · NADCAP CP through Feb 28, 2027 · AS9100D · Worldwide shipping